Venmar THH 1.0 Installationsanleitung

Stöbern Sie online oder laden Sie Installationsanleitung nach Kamine Venmar THH 1.0 herunter. Venmar THH 1.0 Installation guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
INSTALLATION GUIDE FOR
VENMAR AVS UNITS
CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV
RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
06010A rev. K
Model no.: 41502
(HRV with ports on top)
Model no.: 41500
(HRV with ports on sides)
Model no.: 41506
(ERV with ports on top)
Model no.: 41504
(ERV with ports on sides)
VB0069
VB0071
VB0074
VB0070
These products earned the ENERGY STAR
®
by
meeting strict energy efficiency guidelines set
by Natural Resources Canada and the US EPA.
They meet ENERGY STAR requirements only
when used in Canada.
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - VENMAR AVS UNITS

INSTALLATION GUIDE FORVENMAR AVS UNITSCONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERVRESIDENTIAL USE ONLYREAD AND SAVE THESE INSTRUCTIONS06010A rev. KModel

Seite 2 - LIMITATION

Choose an appropriate location to install the exteriorhoods:• There must be a minimum distance of 6’ (1.8 m)between the hoods to avoid cross-contamina

Seite 3 - TABLE OF CONTENTS

3. CONTROLS (CONT’D)- 11 -For more convenience, this unit can also be controlled using an optional main wall control. NOTES: 1. The integrated control

Seite 4 - 1. TYPICAL INSTALLATIONS

3. CONTROLS (CONT’D)3.2.4 ELECTRICAL CONNECTION TO OPTIONAL AUXILIARY WALL CONTROLSNOTE: If an optional auxiliary wall control isactivated and then, t

Seite 5 - Section 6

5. WIRING DIAGRAMField wiringremote control(see notes 3 & 4)120 V, 60 HzW1J5J7J6J4ELECTRONICASSEMBLY1231212123123412123 4512345J8J9J11J1012J12J13J

Seite 6 - Latches in front of the unit

6.1 WHAT YOU NEED TO BALANCE THE UNIT• A magnehelic gauge capable of measuring 0 to 0.5 inch of water (0 to 125 Pa) and 2 plastic tubes.• The balancin

Seite 7

7. CONNECTING THE DRAIN (HRV UNITS ONLY)VO0091 VO0093 VO0092 To drainIn order to keep the drain pan intact, handtighten the 2 plastic drain fittings t

Seite 8

*PART NOT SHOWN.VL00198. SERVICE PARTS1233121113478945610- 16 -REF.NO.DESCRIPTIONPARTNUMBER41500 HRVPORTS ON SIDES41502 HRVPORTS ON TOP41504 ERVPORTSO

Seite 9

If the integrated control LED of the unit is flashing, this means the unit sensors detected a problem. See the table below to know where on the unit t

Seite 10 - 2. INSTALLATION (CONT’D)

Problems Possible causes You should try this9. The supply and/or exhaust • The circuit board may be defective. • Press on the integrated control push

Seite 11 - 3. CONTROLS (CONT’D)

ABOUT THIS MANUALBecause of the large amount of models covered by this publication, the illustrations are typical ones. Some details of your unit may

Seite 12

TABLE OF CONTENTS- 3 -1. TYPICAL INSTALLATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 13 - 5. WIRING DIAGRAM

Stale air coming from the registers located at the highest level of the houseis exhausted to the outside. Fresh air from outside is filtered and suppl

Seite 14 - 6. BALANCING THE UNIT

1. TYPICAL INSTALLATIONS (CONT’D)1.4 ATTIC INSTALLATION FOR ERV UNITS ONLYAll 3 types of installations can be used in the attic (Fully ducted system,

Seite 15 - Tie-wrap

2. INSTALLATION (CONT’D)2.3 UNIT PREPARATION (CONT’D)The door latches location can be changed from sides to front of the unit, according to the instal

Seite 16 - 8. SERVICE PARTS

2. INSTALLATION (CONT’D)2.5 PLANNING OF THE DUCTWORK• Keep it simple. Plan for a minimum of bends and joints. • Keep the length of insulated ducts to

Seite 17 - 9. TROUBLESHOOTING

2.6 INSTALLING THE DUCTWORK AND REGISTERS (CONT’D)2.6.3 SIMPLIFIED INSTALLATION (AS ILLUSTRATED IN SECTION 1.3)There are 2 methods for connecting the

Seite 18 - 9. TROUBLESHOOTING (CONT’D)

Rigid ductsUse a small length of flexible duct to connect the rigid duct to the ports in order to avoid vibration transmissions. Use tie-wraps to perf

Kommentare zu diesen Handbüchern

Keine Kommentare